Measurement of hydrogen radical concentration in DBD ingited at different frequencies
| Authors | |
|---|---|
| Year of publication | 2024 |
| Type | Conference abstract |
| MU Faculty or unit | |
| Citation | |
| Description | We measured concentration of hydrogen radicals in DBD at different frequencies. It showed promising results (high concentration) at high frequencies. We will continue the research using a better DBD cuvette. |